Euroball III Data Acquisition

Event Builder

Super-Event fragment buffers of the same events collected in the Readout Units are sent in parallel via the FCS switch to the same destination processor to be analysed. The fragments are tagged with the event number within the ROCOs.

The event builder function includes tasks such as:-

All data sources (ROCOs and FERA masters) are required to generate an event fragment even if it contains no data. This is important for the event construction since it is possible to detect a missing event fragment or malfunctioning data source which would not be the case if empty fragments were not required.